Package price per terahash. Shipping and installation are quoted separately.
The HeatCore MS100 is an indoor ten-miner hydro rack with integrated PDU, coolant distribution, networking, monitoring, and an optional heating loop. It delivers factory-prefabricated mining capacity while recovering up to 100 kW of heat for larger homes or commercial buildings.
The items below come from the current product description and catalog fields; final package scope is confirmed in the quote.
Review the catalog specifications and request a site-specific configuration.
Use the published specifications as a starting point. Confirm the final package against your site and miner fleet before ordering.
Check available capacity, voltage and connection design for the intended full load.
Review water-loop or ventilation interfaces, ambient conditions and heat rejection at the deployment site.
Confirm miner compatibility, included components, installation scope, delivery location and lead time in the quote.
| Model | MS100 for Whatsminer |
|---|---|
| Capacity | 10 |
| Cooling | Hydro Cooling + Heat Recovery |
| Power Consumption | 103 kW max |
| Input Voltage | 3-phase 400-480V 50/60Hz |
| Size | 800 x 1000 x 2050 mm |
| Weight | 330 kg |
| Condition | New |
| Miner Capacity | 10 Slots |
| Integrated System | Rack, PDU, SCS/CDU, manifold, network, dry cooler and piping |
| Dimensions (L x W x H) | 800 x 1000 x 2050 mm |
| Net / Operating Weight | 330 kg / 600 kg |
| Maximum Operation Power | 103 kW |
| Maximum IT Power | 100 kW |
| Rated Voltage | IEC: 3-phase 400V 50Hz; NEC: 3-phase 415-480V 60Hz |
| Maximum Operating Current | 200 A |
| Heating Loop Heat Exchange | 100 kW |
| Heating Loop Supply / Return | 40 C / 55 C |
| Heating Loop Rated Flow | 6 m3/h |
| Heating Loop Maximum Pressure | 10 bar |
| Internal Loop Coolant | Distilled water + antifreeze + corrosion inhibitor |
| Internal Loop Supply / Return | 45 C / 60 C |
| Internal Loop Rated Flow | 6 m3/h |
The catalog names 10 x WhatsMiner M6DS++ 583T. Confirm the exact hardware revision and connection layout with the project team.
The catalog lists 103 kW max and 3-phase 400-480V 50/60Hz. Have your electrical designer confirm site capacity and connection details for the intended fleet.
The final quote confirms equipment, miner supply, freight, installation scope and lead time.
Our experts can help you build a more efficient and profitable operation.
Whatsminer M6DS++ (583Th)583 Th · 15.5 J/Th10 x WhatsMiner M6DS++ 583T10 slotsMiner net profit $13.65/dayEst. $136.47/day full loadMiner earnings use the current catalog data and $0.045/kWh electricity. Full-load figures assume the same miner in every slot and exclude cabinet pumps, fans and other auxiliary loads.
| Operating Environment | Outdoor -25 to 45 C; indoor 5 to 40 C |
|---|
| Indoor Relative Humidity | 5% RH to 95% RH, non-condensing |
|---|
| Protection Grade | IP20 |
|---|
| Monitoring | HeatCore Cloud remote monitoring and API control |
|---|